4
 
Model:ALF
 Product accent:
  • The flow-directing mechanism in the valve can guide the flow and stabilize pressure.
  • In the corner of pipe, the water hammer is the most obvious. The design is for meeting the requirement and set the arrester at the corner directly. This design not only saves the space and is easy to set up, but also can replace the traditional crooked head to reduce the cost of setting up.
  • L style absorbs water hammer effect in two ways and brings excellent result.
 

彎頭型水錘規格表

【備註】
  • The test pressure of valve body:
    Cast Iron & Bronze:12kgf/cm2
  • tainless steel :35kgf/cm2
  • Diaphragm material: NBR
  • Applied temperature:-15℃ ~ 80℃
  • Applied conditions: Fluid
 
   

               

Flange type (Material : Cast Iron or Stainless Steel)
No A B C Air Chamber
2" 230 110 105 1490cm3
2.5" 260 130 115 2130cm3
3" 275 140 125 2465cm3
4" 345 155 150 5535cm3
6" 467 200 200 15325cm3
8" 560 235 232 27230cm3

尺寸單位:mm


彎頭型水錘防止器安裝場合說明

 

 

When pump shuts off, pressure decreases instantly and forms unstable gap of positive and negative pressure that causes water hammer effect and creates noise and pipe vibration. To set up water hammer arrester at the pipe corner upside of the pump (shown as the figure) can prevent the water hammer effect and protect the machine.

★Remark:When lift is longer than 50m and pressure is above 5 kgf/cm2, we suggest to set up arresters each at the downside of the long pipe and the upside corner of the check valve.
 
  It's easy to cause water hammer effect when the gate closes fast. To set up arrester at the first corner away from the fast-shut-down valve can Absorb and prevent the water hammer effect directly and eliminate the noise.
 
                     

 

When the fluids flow through the serial corner, the change of flow speed and direction and friction effect will cause unstable pressure wave, which will lead to vibration and noise. To set up arrester and silent check valve can eliminate the pressure wave.

     

Remark:

  • The pressure meter on the valve will show the air chamber pressure before piping and show the pipe? pressure after piping.
  • To leave a 10 cm opening between valve and wall for easy to maintain.
  • Considering the high-pressure situation, cast iron or stainless steel valve body is suggested for the? valve which diameter is larger than 2".
  • When lift is longer than 50m and pressure is above 5 kgf/cm2, we suggest to set up arrester each at the Downside of the long pipe and the corner upside of the check Valve.
  • Before installation, make sure the pressure of water hammer arrester air chamber is lower than pipepressure.
  • When the pressure of the air chamber of the water hammer arrester is maintained at the 60% ~ 90% of pipe pressure, the arrester will have the best water-hammer-preventing result.
  • If the water pressure in the pipe is lower or the air pressure of the arrester air chamber is lower, both can be corrected by pumped into air or release air from the air-pumping hole at the top of the arrester.
  • When the Outlet is under open pressure like float valve, bathroom equipment and faucet, input pressure 1 ~ 1.3 kgf/cm2 is preferred.
Z-Tide Valves Industrial Co.,Ltd     
       TEL:(02)2999-8885•FAX:(02)2999-7456•E-mail: zt.valve@msa.hinet.net 
 Official Exporting Department :    Elite Line Industrial Corporation
上海地區銷售代理商 上海僑鼎閥門有限公司
We reserve the right to change the specifications listed in catalogues and the website without notice. c 2008 Z-Tide Valves All Rights Reserved.